Magnetrol - Pulse Burst Radar
|
Pulsar®
Model RX5
Radar Transmitter |
SYSTEM DESIGN |
|
Measurement Principle |
Pulse Burst Radar @ 5.8 GHz (Europe), 6.3 GHz (U.S.) |
|
INPUT |
|
Measured Variable |
Level, determined by the time-of-flight of a radar pulse from the |
|
|
transmitter to the product surface and back |
|
Zero and Span |
0.5 to 65 feet (0.2 to 20 meters) |
|
OUTPUT |
|
Type |
Analog: 4–20 mA or 4–20 mA with optional HART digital signal |
|
Range |
Analog: 3.8 to 20.5 mA useable; Digital: 0 to 999" (0 to 999 cm) |
|
Resolution |
Analog: 0.01 mA; Digital: 0.1" |
|
Loop Resistance |
GP/IS/XP 350 Ω @ 24 VDC/22 mA; 400 Ω @ 24 VDC/20 mA |
|
Diagnostic Alarm |
Adjustable 3.6 mA, 22 mA, HOLD |
|
Damping |
Adjustable 0–45 |
|
USER INTERFACE |
|
Keypad |
Three-button, menu-driven data entry and system security |
|
Indication |
Two-line × eight-character display |
|
Digital Communication |
HART version 5 compatible (communicator sold separately) |
|
POWER (Measured at instrument terminals) |
|
|
GP: 16 to 36 VDC; IS: 16 to 28.6 VDC; XP: 16 to 36 VDC |
|
HOUSING |
|
Material |
Aluminum A356T6 (< 0.25% copper), 316 stainless steel (optional) |
|
Cable Entry |
3⁄4" NPT, M20 |
|
ANTENNAS |
|
Type |
TFE, polypropylene or Halar dielectric rod / 3" 4" or 6" horn |
|
Materials (wetted parts) |
Dielectric rod: TFE, polypropylene or Halar |
|
|
Mounting nut: 316 SS (Hastelloy C, Monel, or All-Polypropylene optional) |
|
|
Viton® O-rings (standard) |
|
|
Horn: 316 stainless steel (Hastelloy C optional) |
|
|
Insert: TFE |
|
|
Viton O-rings (standard) |
|
Process Connections |
Dielectric rods: 11⁄2" NPT and BSP; ANSI or DIN flanges |
|
|
Horns: 4" or 6" ANSI or DIN flanges |
|
Maximum Process Temperature |
+400° F (+204° C) |
|
Maximum Process Pressure |
750 psi (51.7 bar) |
|
Minimum Dielectric |
2.0 dielectric rods / 1.7 horns |
|
ENVIRONMENT |
|
Operating Temperature Range |
-40° to +175° F (-40° to +80° C) |
|
LCD Operating Temp. Range |
-5° to +160° F (-20° to +70° C) |
|
Storage Temperature |
-50° to +175° F (-46° to +80° C) |
|
Humidity |
0-99%, non-condensing |
|
Electromagnetic Compatibility |
Meets CE requirements EN 50081-2, EN 50082-2 |
|
PERFORMANCE (Reference: Reflection from ideal reflector at +70° F / +20° C) |
|
Linearity |
±0.4" or 0.1% of tank height |
|
Measured Error |
±0.4" or 0.1% of tank height |
|
Resolution |
0.1" |
|
Repeatability |
±0.2" or 0.05% of tank height |
|
Warm-up Time |
30 seconds |
|
Ambient Temperature Effect |
Temperature effect 0.05% per 10° C |
|
Process Dielectric Effect |
< 0.3 inch within selected range |
|
Maximum Rate of Change |
15 feet (4.5 meters) / minute |
|
|
|