Magnetrol - Pulse Burst Radar

Products > Magnetrol > Pulse Burst > Pulsar RX5


Pulsar® Model RX5 Radar Transmitter

SYSTEM DESIGN
  Measurement Principle Pulse Burst Radar @ 5.8 GHz (Europe), 6.3 GHz (U.S.)
INPUT
  Measured Variable Level, determined by the time-of-flight of a radar pulse from the
    transmitter to the product surface and back
  Zero and Span 0.5 to 65 feet (0.2 to 20 meters)
OUTPUT
  Type Analog: 4–20 mA or 4–20 mA with optional HART digital signal
  Range Analog: 3.8 to 20.5 mA useable; Digital: 0 to 999" (0 to 999 cm)
  Resolution Analog: 0.01 mA; Digital: 0.1"
  Loop Resistance GP/IS/XP 350 Ω @ 24 VDC/22 mA; 400 Ω @ 24 VDC/20 mA
  Diagnostic Alarm Adjustable 3.6 mA, 22 mA, HOLD
  Damping Adjustable 0–45
USER INTERFACE
  Keypad Three-button, menu-driven data entry and system security
  Indication Two-line × eight-character display
  Digital Communication HART version 5 compatible (communicator sold separately)
POWER (Measured at instrument terminals)
    GP: 16 to 36 VDC; IS: 16 to 28.6 VDC; XP: 16 to 36 VDC
HOUSING
  Material Aluminum A356T6 (< 0.25% copper), 316 stainless steel (optional)
  Cable Entry 3⁄4" NPT, M20
ANTENNAS
  Type TFE, polypropylene or Halar dielectric rod / 3" 4" or 6" horn
  Materials (wetted parts) Dielectric rod: TFE, polypropylene or Halar
    Mounting nut: 316 SS (Hastelloy C, Monel, or All-Polypropylene optional)
    Viton® O-rings (standard)
    Horn: 316 stainless steel (Hastelloy C optional)
    Insert: TFE
    Viton O-rings (standard)
  Process Connections Dielectric rods: 11⁄2" NPT and BSP; ANSI or DIN flanges
    Horns: 4" or 6" ANSI or DIN flanges
  Maximum Process Temperature +400° F (+204° C)
  Maximum Process Pressure 750 psi (51.7 bar)
  Minimum Dielectric 2.0 dielectric rods / 1.7 horns
ENVIRONMENT
  Operating Temperature Range -40° to +175° F (-40° to +80° C)
  LCD Operating Temp. Range -5° to +160° F (-20° to +70° C)
  Storage Temperature -50° to +175° F (-46° to +80° C)
  Humidity 0-99%, non-condensing
  Electromagnetic Compatibility Meets CE requirements EN 50081-2, EN 50082-2
PERFORMANCE (Reference: Reflection from ideal reflector at +70° F / +20° C)
  Linearity ±0.4" or 0.1% of tank height
  Measured Error ±0.4" or 0.1% of tank height
  Resolution 0.1"
  Repeatability ±0.2" or 0.05% of tank height
  Warm-up Time 30 seconds
  Ambient Temperature Effect Temperature effect 0.05% per 10° C
  Process Dielectric Effect < 0.3 inch within selected range
  Maximum Rate of Change 15 feet (4.5 meters) / minute