Magnetrol - Pulse Burst Radar

Products > Magnetrol > Pulse Burst Radar > Model R82


Model R82 Radar Transmitter and Sensor

SYSTEM DESIGN
  Measurement Principle Pulse Burst Radar @ 26 GHz
INPUT
  Measured Variable Level, determined by the time-of-flight of a radar pulse from the
    transmitter to the product surface and back
  Zero and Span 15" to 40 feet (0.4 to 12.2 m) as measured from threads
OUTPUT
  Type Analog: 4–20 mA with optional HART digital signal
  Range Analog: 3.8 to 20.5 mA useable (Namur NE43)
    Digital: 0 to 999" (0 to 9999 cm)
  Resolution Analog: 0.01 mA
    Digital: 0.1"
  Loop Resistance GP/IS/XP 400 Ω @ 24 VDC/20 mA; 350 Ω @ 24 VDC/22 mA
  Diagnostic Alarm Adjustable 3.6 mA, 22 mA, HOLD
  Damping Adjustable 0–45
  Output at Antenna < 0.1 mW (avg), < 2 mW (max)
USER INTERFACE
  Keypad Four-button, menu-driven data entry and system security
  Indication Two-line × 16-character display
  Digital Communication HART Version 5 compatible
POWER (Measured at instrument terminals)
  General Purpose/Intrinsically Safe 16 to 36 VDC
HOUSING
  Material Lexan base and cover or
    Cast aluminum A356T6 (< 0.2% copper)
  Cable Entry 3⁄4" NPT, M20
  Ingress Protection Lexan Housing: NEMA 6P (IP67/68
    Aluminum Housing: NEMA 4X/6P (IP67/68)
ANTENNAS Encapsulated Horn: Polypropylene or Tefzel` (optional)
  Wetted Surfaces Polypropylene or Tefzel
  Maximum Process Temperature -40 to +200° F (-40 to +93° C) @ atmos
  Maximum Process Pressure Vacuum to 200 psig @ +70° F (-14.5 to 13.8 bar)
  Minimum Dielectric 1.7 (application dependent)
  Process Connections 2" NPT/BSP sanitary flanges
ENVIRONMENT
  Operating Temperature Range -40° to +175° F (-40° to +80° C)
  LCD Operating Temp. Range -5° to +160° F (-20° to +70° C)
  Storage Temperature -50° to +175° F (-46° to +80° C)
  Humidity 0-99%, non-condensing
  Electromagnetic Meets CE requirements EN 50081-2, EN 50082-2
PERFORMANCE (Reference: Reflection from ideal reflector at +70° F / +20° C)
  Reference Conditions Reflection from ideal reflector at +70° F (+20° C)
  Linearity ±0.2" (5 mm) or 0.05% of tank height (whichever is greater)
  Measured Error ±0.2" (5 mm) or 0.05% of tank height (whichever is greater)
  Resolution 0.1" (2.5 mm)
  Repeatability ±0.1" (2.5 mm) or 0.025% of tank height
  Warm-up Time 30 seconds
  Ambient Temperature Effect 0.05% per 10° C
  Process Dielectric Effect < 0.3 inch within selected range
  Maximum Rate of Change 180 inches (450 cm) / minute