Magnetrol - Pulse Burst Radar
|
Model R82 Radar Transmitter and Sensor
|
SYSTEM DESIGN |
|
Measurement Principle |
Pulse Burst Radar @ 26 GHz |
|
INPUT |
|
Measured Variable |
Level, determined by the time-of-flight of a radar pulse from the |
|
|
transmitter to the product surface and back |
|
Zero and Span |
15" to 40 feet (0.4 to 12.2 m) as measured from threads |
|
OUTPUT |
|
Type |
Analog: 4–20 mA with optional HART digital signal |
|
Range |
Analog: 3.8 to 20.5 mA useable (Namur NE43) |
|
|
Digital: 0 to 999" (0 to 9999 cm) |
|
Resolution |
Analog: 0.01 mA |
|
|
Digital: 0.1" |
|
Loop Resistance |
GP/IS/XP 400 Ω @ 24 VDC/20 mA; 350 Ω @ 24 VDC/22 mA |
|
Diagnostic Alarm |
Adjustable 3.6 mA, 22 mA, HOLD |
|
Damping |
Adjustable 0–45 |
|
Output at Antenna |
< 0.1 mW (avg), < 2 mW (max) |
|
USER INTERFACE |
|
Keypad |
Four-button, menu-driven data entry and system security |
|
Indication |
Two-line × 16-character display |
|
Digital Communication |
HART Version 5 compatible |
|
POWER (Measured at instrument terminals) |
|
General Purpose/Intrinsically Safe |
16 to 36 VDC |
|
HOUSING |
|
Material |
Lexan base and cover or |
|
|
Cast aluminum A356T6 (< 0.2% copper) |
|
Cable Entry |
3⁄4" NPT, M20 |
|
Ingress Protection |
Lexan Housing: NEMA 6P (IP67/68 |
|
|
Aluminum Housing: NEMA 4X/6P (IP67/68) |
|
ANTENNAS Encapsulated Horn: Polypropylene or Tefzel` (optional) |
|
Wetted Surfaces |
Polypropylene or Tefzel |
|
Maximum Process Temperature |
-40 to +200° F (-40 to +93° C) @ atmos |
|
Maximum Process Pressure |
Vacuum to 200 psig @ +70° F (-14.5 to 13.8 bar) |
|
Minimum Dielectric |
1.7 (application dependent) |
|
Process Connections |
2" NPT/BSP sanitary flanges |
|
ENVIRONMENT |
|
Operating Temperature Range |
-40° to +175° F (-40° to +80° C) |
|
LCD Operating Temp. Range |
-5° to +160° F (-20° to +70° C) |
|
Storage Temperature |
-50° to +175° F (-46° to +80° C) |
|
Humidity |
0-99%, non-condensing |
|
Electromagnetic |
Meets CE requirements EN 50081-2, EN 50082-2 |
|
PERFORMANCE (Reference: Reflection from ideal reflector at +70° F / +20° C) |
|
Reference Conditions |
Reflection from ideal reflector at +70° F (+20° C) |
|
Linearity |
±0.2" (5 mm) or 0.05% of tank height (whichever is greater) |
|
Measured Error |
±0.2" (5 mm) or 0.05% of tank height (whichever is greater) |
|
Resolution |
0.1" (2.5 mm) |
|
Repeatability |
±0.1" (2.5 mm) or 0.025% of tank height |
|
Warm-up Time |
30 seconds |
|
Ambient Temperature Effect |
0.05% per 10° C |
|
Process Dielectric Effect |
< 0.3 inch within selected range |
|
Maximum Rate of Change |