Magnetrol - Thermatel TG1

Products > Magnetrol > Thermal Dispersion > Level/Flow Switches

General Description
Magnetrol’s TG1/TG2 switch is the industry’s only two-wire, intrinsically- safe thermal dispersion switch. The switch consists of a probe and preamplifier with remote DIN rail electronics. Barriers in the DIN rail enclosure provide a two-wire, intrinsically-safe circuit to the probe/preamplifier.
 
Product Operation
The preamplifier converts the temperature difference to a pulse signal which is super-imposed on the two wires providing power to the sensor. The DIN rail electronics provide operation control including set point adjustment, LED indication of flow/level, relay, fail-safe adjustment, and time delay. A non-linear mA output signal is available for diagnostics and repeatable flow/level indication.
   
Features
  • DIN rail mounted electronics with built-in barrier provide a
  • two-wire intrinsically-safe circuit to the probe/preamplifier
  • Versatile switch for flow and level
  • Set point adjustment at remote electronics
  • Up to 1,650 feet (500 meters) cable length
  • LED indication provides monitoring of actual flow/level
  • mA output signal will provide repeatable indication plus
  • can be used for diagnostics
  • Uses all Thermatel probes including low flow body and
  • high-temperature sensor
  •  
    Applications:
    Flow:
    Liquid or gas flow, pump protection, cooling air/water, relief valves, flow/no flow
    Level:
    Hi/Low level, high viscosity media, high solids content, aeration/foaming, sanitary applications, interface detection, hightemperature applications